DRG 244
Surgical DRGPermanent Cardiac Pacemaker Implant without CC/MCC
What is MS-DRG 244?
MS-DRG 244 is a Surgical Medicare Severity Diagnosis Related Group under Major Diagnostic Category 05 (MDC 05) without a significant Complication or Comorbidity. Hospitals use this grouping to determine reimbursement for inpatient stays under Medicare.
Linked ICD-10-PCS Procedure Mappings
- 02HM3JZ
Insertion of Pacemaker Lead into Ventricular Septum, Percutaneous Approach
BillableSection 0 - 02HM3MZ
Insertion of Cardiac Lead into Ventricular Septum, Percutaneous Approach
BillableSection 0 - 0JH604Z
Insertion of Pacemaker, Single Chamber into Chest Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH605Z
Insertion of Pacemaker, Single Chamber Rate Responsive into Chest Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH606Z
Insertion of Pacemaker, Dual Chamber into Chest Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH607Z
Insertion of Cardiac Resynchronization Pacemaker Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH60PZ
Insertion of Cardiac Rhythm Related Device into Chest Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH634Z
Insertion of Pacemaker, Single Chamber into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH635Z
Insertion of Pacemaker, Single Chamber Rate Responsive into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH636Z
Insertion of Pacemaker, Dual Chamber into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH637Z
Insertion of Cardiac Resynchronization Pacemaker Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH63PZ
Insertion of Cardiac Rhythm Related Device into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH804Z
Insertion of Pacemaker, Single Chamber into Abdomen Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH805Z
Insertion of Pacemaker, Single Chamber Rate Responsive into Abdomen Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH806Z
Insertion of Pacemaker, Dual Chamber into Abdomen Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH807Z
Insertion of Cardiac Resynchronization Pacemaker Pulse Generator into Abdomen Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH80PZ
Insertion of Cardiac Rhythm Related Device into Abdomen Subcutaneous Tissue and Fascia, Open Approach
BillableSection 0 - 0JH834Z
Insertion of Pacemaker, Single Chamber into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH835Z
Insertion of Pacemaker, Single Chamber Rate Responsive into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH836Z
Insertion of Pacemaker, Dual Chamber into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH837Z
Insertion of Cardiac Resynchronization Pacemaker Pulse Generator into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - 0JH83PZ
Insertion of Cardiac Rhythm Related Device into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
BillableSection 0 - X2HN37B
Insertion of Endocardiac Pacing Electrode into Left Ventricle, Percutaneous Approach, New Technology Group 11
BillableSection X
