MS-DRG 211Surgical
Cardiac Pacemaker Revision or Device Replacement without MCC
Major Diagnostic Category 05·Grouped by procedure·FY 2027
MS-DRG 211 is a Surgical Medicare Severity Diagnosis Related Group under Major Diagnostic Category 05 (MDC 05) without a significant Complication or Comorbidity. For FY 2027 it carries a relative weight of 1.8091 with a geometric mean length of stay of 2.6 days and an arithmetic mean of 3.3 days. Hospitals use this grouping to determine reimbursement for inpatient stays under Medicare.
Advertisements
FY 2027 payment data
From Table 5 of the FY 2027 IPPS Final Rule (CMS).
- Relative weight:
- 1.8091 (payment multiplier vs. the average case (1.0))
- Geometric mean stay:
- 2.6 days (used for transfer payments)
- Average stay:
- 3.3 days (arithmetic mean)
- Post-acute transfer policy:
- Yes (early transfers can be paid less)
Same condition, other severity levels
CMS splits one condition into separate DRGs by how sick the patient is. With MCC pays more than with CC, which pays more than without CC/MCC.
| DRG | Title | Relative weight | Mean stay |
|---|---|---|---|
| 210 | Cardiac Pacemaker Revision or Device Replacement with MCC | 3.2640 | 5.4 days |
| 211 | Cardiac Pacemaker Revision or Device Replacement without MCC (this page) | 1.8091 | 2.6 days |
Procedure codes (34)
ICD-10-PCS procedures that can group a stay to DRG 211.
- 02H63DZInsertion of Intraluminal Device into Right Atrium, Percutaneous Approach
- 02H73DZInsertion of Intraluminal Device into Left Atrium, Percutaneous Approach
- 02HK00ZInsertion of Pressure Sensor Monitoring Device into Right Ventricle, Open Approach
- 02HK02ZInsertion of Monitoring Device into Right Ventricle, Open Approach
- 02HK0YZInsertion of Other Device into Right Ventricle, Open Approach
- 02HK32ZInsertion of Monitoring Device into Right Ventricle, Percutaneous Approach
- 02HK3DZInsertion of Intraluminal Device into Right Ventricle, Percutaneous Approach
- 02HK3YZInsertion of Other Device into Right Ventricle, Percutaneous Approach
- 02HK40ZInsertion of Pressure Sensor Monitoring Device into Right Ventricle, Percutaneous Endoscopic Approach
- 02HK42ZInsertion of Monitoring Device into Right Ventricle, Percutaneous Endoscopic Approach
- 02HK4YZInsertion of Other Device into Right Ventricle, Percutaneous Endoscopic Approach
- 02HL3DZInsertion of Intraluminal Device into Left Ventricle, Percutaneous Approach
- 02HL4YZInsertion of Other Device into Left Ventricle, Percutaneous Endoscopic Approach
- 02HM3YZInsertion of Other Device into Ventricular Septum, Percutaneous Approach
- 02PA0MZRemoval of Cardiac Lead from Heart, Open Approach
- 02PA3MZRemoval of Cardiac Lead from Heart, Percutaneous Approach
- 02PA4MZRemoval of Cardiac Lead from Heart, Percutaneous Endoscopic Approach
- 02WA0MZRevision of Cardiac Lead in Heart, Open Approach
- 02WA3MZRevision of Cardiac Lead in Heart, Percutaneous Approach
- 02WA4MZRevision of Cardiac Lead in Heart, Percutaneous Endoscopic Approach
- 0JH600ZInsertion of Hemodynamic Monitoring Device into Chest Subcutaneous Tissue and Fascia, Open Approach
- 0JH602ZInsertion of Monitoring Device into Chest Subcutaneous Tissue and Fascia, Open Approach
- 0JH630ZInsertion of Hemodynamic Monitoring Device into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JH632ZInsertion of Monitoring Device into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JH800ZInsertion of Hemodynamic Monitoring Device into Abdomen Subcutaneous Tissue and Fascia, Open Approach
- 0JH830ZInsertion of Hemodynamic Monitoring Device into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JPT0PZRemoval of Cardiac Rhythm Related Device from Trunk Subcutaneous Tissue and Fascia, Open Approach
- 0JPT3PZRemoval of Cardiac Rhythm Related Device from Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JWT02ZRevision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, Open Approach
- 0JWT0PZRevision of Cardiac Rhythm Related Device in Trunk Subcutaneous Tissue and Fascia, Open Approach
- 0JWT0YZRevision of Other Device in Trunk Subcutaneous Tissue and Fascia, Open Approach
- 0JWT32ZRevision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JWT3PZRevision of Cardiac Rhythm Related Device in Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach
- XHH80HBInsertion of Ultrasound Transmitter and Battery for Endocardiac Pacing Electrode into Chest Subcutaneous Tissue and Fascia, Open Approach, New Technology Group 11